Content Strategy Manager
Meter Bridge, the slide wire bridge, is an instrument that works on the principle of a Wheatstone bridge. It is one of the systems under Current electricity Mechanism. Meter Bridge has a uniform cross sectional area stretched tightly and clamped between two thick metallic strips which bent at right angles. It is basically used to measure the resistance of wires, coils or any other material.
Table of Content |
Key Takeaways: Capacitance, Electric Charge, Electric Potential, Current Electricity, Meter bridge, Wire bridge, Electric current, Flow rate, Angle
Current Electricity
[Click Here for Sample Questions]
- The flow of electric charge is known as electric current. It is calculated as a charge flow rate. It refers to the volume of charge flowing over time.
- Consider a charge of 20Coulomb flowing at a rate of one per second.
- Then it becomes 20Coulomb/sec.
- I stand for electric current.
- It's written as I=dQ/dt, where dQ is the rate of charge shift over time.
- Ampere is a unit of measurement (A).
Discover about the Chapter video:
Current Electricity Detailed Video Explanation:
Also Read:
What is Meter Bridge?
[Click Here for Previous Year Questions]
A Meter connect is a sort of electrical circuit utilized in estimating an electrical obstruction, which is obscure by adjusting its two legs of the scaffold circuit, where one of the legs incorporates an obscure segment. The Wheatstone Bridge can in any case be utilized in estimating light estimations of protections around the scope of milli-Ohms.
Read More: Electric Charges and Fields Notes
How does Meter Bridge use the Unknown Resistance?
A meter connect is a device used in finding the obscure opposition of a curl. Underneath figure 12 is the graph of a valuable meter connect instrument.
In the above figure, R is called the Resistance, P is the Resistance running over AB, S is the Unknown Resistance, Q is the Resistance between the joints BD.
AC is the long wire estimating 1m long and it is made of constantan or manganin having a uniform territory of the cross-area Such that L1 + L2 = 100
Expecting that L1 = L => L2 = 100 – L
Connection acquires the obscure obstruction 'X' of the given wire:
X = RL2/L1 = R(100 – L)/L
Read More: Unit of Voltage
What's more, the particular obstruction of the material for a given wire is gotten by the connection = (3.14) r2X/l
where r = the sweep of the link and l = length of the wire.
The device needed in finding the obscure opposition of a conductor utilizing a meter connect are:
|
Also Read: Verify the laws of parallel combination of resistances using a metre bridge experiment
How to Find Unknown Resistance Using Meter Bridge?
To find the unknown resistance using meter bridge, given below step-by-step procedure must be followed:
- Gather the instruments and get ready associations as demonstrated in the above figure.
- Take some appropriate sort of obstruction 'R' from the opposition box.
- Contact jockey at point A; look that there exists an avoidance in the galvanometer on one of the sides, at that point contact the rider on point C of wire, at that point the diversion in the galvanometer must be on another side.
- Discover the situation of the invalid point having redirection in the galvanometer that gets zero.
- Proceed with the above strategy for various estimations of the 'R'. Note probably around 5 readings.
- Consider where the galvanometer shows a 0 avoidance; this is known as the equilibrium point.
- Presently, Measure the length of a given wire by the utilization of standard scale and range of the wire by the usage of a screw check, (Take in any event five readings).
- Compute Mean Resistance of Single Unknown Resistance = Total Sum of protections of Unknown opposition from the over five readings)/5.
Read More:
Things to Remember
- Meter Bridge is used to find the unknown resistance of a conductor as that of in a wheatstone bridge.
- A Meter connect is a sort of electrical circuit utilized in estimating an electrical obstruction. which is obscure by adjusting its two legs of the scaffold circuit, where one of the legs incorporates an obscure segment.
- The flow of electric charge is known as electric current. It is calculated as a charge flow rate. It refers to the volume of charge flowing over time.
- Amperes is a unit of measurement (A).
- Samuel Hunter Christie made this instrument in the year 1833 and was improved and rearranged by Sir Charles Wheatstone in the year 1843.
Previous Year Questions
- Potometer is used to measure…
- In the circuit shown in the given figure, the resistances R1 and R2 are respectively….
- In the circuit shown below, the potential of….
- Potometer works on the principle of...
- Value of R for which the power delivered in it is maximum is given by... [ NEET 1992 ]
- In a potentiometer the null point is received at 7th wire… [DUET 2007]
- The electrical permittivity and magnetic permeability of free space are… [DUET 2003]
- In a potentiometer circuit a cell of EMF 1.5V gives balance point at 36cm length… [NEET 2021]
- A2V battery, a 15Ω resistor and a potentiometer of 100cm length… [jcece 2011]
- In the circuit given in figure, 1 and 2 are ammeters… [KEAM 1999]
- In the circuit shown in figure, neglecting source resistance, the voltmeter and ammeter… [KCET 2001]
- A horizontal rod of mass 0.01kg and length10cm is placed on a frictionless plane inclined… [VITEEE 2015]
- A current of 5A is passing through a metallic wire of cross-sectional area… [VITEEE 2006]
- Charge passing through a conductor of cross-section area… [VITEEE 2012]
- A square loop, carrying a steady current I, is placed in horizontal plane near… [VITEEE 2012]
- A potentiometer circuit is set up as shown. The potential gradient, across the… [NEET 2010]
- Consider the following two statements. (A) Kirchhoff's junction law follows from… [NEET 2010]
- Three resistances each of 4Ω are connected to form a triangle… [NEET 1993]
- Current through 3Ω resistor is 0.8 ampere, then potential drop through 4Ω resistor is… [NEET 1993]
Check Out:
Sample Questions
Ques. What is a Meter Bridge? For what reason is it purported? [1 mark]
Ans. Meter Bridge is an instrument for looking at protections. It consists of a scaffold wire of length 1m. It has a uniform cross sectional area stretched tightly and clamped between two thick metallic strips which bent at right angles.
Ques. What is the rule of Meter Bridge? [1 mark]
Ans. At the point when the extension is adjusted P/Q = R/S
Ques. Would you be able to discover exceptionally high protections precisely with the assistance of a meter connect? [1 mark]
Ans. No, high protections precisely with the assistance of a meter connect cannot be discovered.
Ques. What is the material of the scaffold: What is the measure for determinations?[1 mark]
Ans. Manganin wire of one meter is used as a scaffold wire. Measure for determination is ‘Low-temperature coefficient’.
Ques. Why are copper strips on the scaffold thick? [1 mark]
Ans. Copper strips on the scaffold thick are placed to limit the obstruction in the meter bridge.
Ques. a) Write the principle of working of a meter bridge. [2 marks]
(b) In a meter bridge, the balance point is found at a distance I1 with resistances R and S as shown in the figure.
An unknown resistance X is now connected in parallel to the resistance S and the balance point is found at a distance I2 . Obtain a formula for X in terms of I2 , I2 and S. [Outside Delhi, 2017, 3 marks]
Ans.
(a) Meter bridge works on the principle of balanced Wheatstone bridge i.e., when the bridge is balancedQues. (a) State the working principle of a meter bridge used to measure an unknown resistance.
(b)Give reason.
(i) why the connections between the resistors in a meter bridge are made of thick copper strips.
(ii) why is it generally preferred to obtain the balance length near the mid-point of the bridge wire.
(c) Calculate the potential difference across the 4 ? resistor in the given electrical circuit, using Kirchhoff’s rules. [Outside Delhi, 2019, 5 marks]
Ans. Meter bridge is a practical apparatus which works on principle of Wheat-Stone bridge. It is used to measure unknown resistance experimentally.
(b) (i) Connection between resistors are made of thick copper strips so that it will have maximum resistance and location of point of balance (D) will be more accurate which results in correct measurement of unknown resistance.
(ii) It is preferred to obtain the balance length near the mid-point of the bridge wire because it increase the sensitivity of meter bridges.
(c) From KCL (Kirchhoff’s current law) at point D
Ques. Two resistances are connected in two gaps of Meter Bridge, and the balance is 20cm from the zero end. A resistance of 15 ohms is connected in series with the smaller of the two. The null point shifts to 40cm. Find the value of the bigger resistance. (3 marks)
Ans. Let P be the smaller resistance and Q be the bigger resistance.
First case → P/Q=2080=14
Second case → (P+15)/Q=4060=23
Comparing both → P/(P+15)=14×32=38
8P = 3P + 45 → 5P = 45 → P = 9 ohms
Therefore, substituting in P/Q = 1/4 → 9/Q = 1/4 → Q = 36 ohms.
Ques. When the radius of the wire is tripled what is the effect on null deflection of galvanometer? (2 marks)
Ans. For a balanced Meter Bridge P/Q = x/(100−x), we can understand that the null deflection of galvanometer does not depend on the radius of the wire. Therefore, even if the radius of the wire is tripled, the null deflection of the galvanometer undergoes no change.
Ques. A resistance of 5 ohms is connected across the gap of a Meter Bridge and an unknown resistance, whih is greater than 5 ohms, is connected across the other gap. When these resistances are interchanged, the balance point shifts by 50 cm. What is the unknown resistance? The length of the wire is 150 cm. (4 marks)
Ans. Let x be the unknown resistance.
First case → 5/x = l/(150–l)
750 – 5l = xl ……….. 1
Second case → x/5 = (l+50)/(100–l)
100 – xl = 5l + 250
xl = 100x – 5l – 250 ………… 2
Comparing 1 and 2
750 – 5l = 100x – 5l – 250
100x = 750 + 250
100x = 1000
x = 10 ohms
Therefore, the unknown resistance is 10 ohms.
Ques. State whether it is true or false: The sensitivity of the meter bridge is at the peak when all resistors have the same order. (2 marks)
Ans. The statement is true.
Explanation: Yes, when all resistors have the same order, the sensitivity of the meter bridge is at the peak. The sensitivity can be increased by keeping the current in the galvanometer high and this can be achieved by reducing the values of the resistors used in the Meter Bridge.
Ques. The four arms of a Wheatstone connect (Fig) have the accompanying protections: AB = 100ω, BC = 10ω, CD = 5ω, and DA = 60Ω.A galvanometer of 15ω obstruction is associated across BD. Compute the current through the galvanometer when a likely contrast of 10 V is kept up across AC.
Ans. Considering the cross-section BADB, we have
100I1 + 15Ig – 60I2 = 0
or on the other hand 20I1 + 3Ig – 12I2= 0 (a)
Considering the lattice BCDB, we have
10 (I1 – Ig) – 15Ig – 5 (I2 + Ig) = 0
10I1 – 30Ig – 5I2 = 0
2I1 – 6Ig – I2 = 0 (b)
Considering the lattice ADCEA,
60I2 + 5 (I2 + Ig) = 10
65I2 + 5Ig = 10
13I2 + Ig = 2 (c)
Increasing Eq. () by 10
20I1 – 60Ig – 10I2 = 0 (d)
From Equations (d) and (a) we have
63Ig – 2I2 = 0
I2 = 31.5Ig [(e)]
Subbing the estimation of I2 into Eq. (c), we get
13 (31.5Ig) + Ig = 2
410.5 Ig = 2
Ig = 4.87 mA.
Ques. In a meter connect (Fig.), the invalid point is found a good way off of 33.7 cm from A. If now opposition of 12ω is associated with S, the invalid point happens at 51.9 cm. Decide the estimations of R and S.
Ans. From the first balance point, we get
(R/S) = (33.7)/ (66.3) = (3.87) (i)
After S is connected with a resistance of 12Ω, the gap changes from S to Seq, where
Seq= (12S)/(S+12) and hence the new balance condition now gives
(51.9)/ (48.1) =(R/ Seq) =R(S+12)/ (12S)
Substituting the value of (R/S) from Eq. (i), we get
(51.9)/ (48.1) = ((S+12)/12) x (33.7)/ (66.3)which gives
S = 13.5Ω. Using the value of (R/S) above, we get
R = 6.86 Ω
For Latest Updates on Upcoming Board Exams, Click Here: https://t.me/class_10_12_board_updates
Check-Out:
Comments